Horizontal Hat Channel Attachment Through High Density Mineral Wool Continuous Exterior Board Insulation
The intent of this Technical Bulletin is to validate the specific structural connection utilized to attach IMETCO’s vented rainscreen horizontal hat channel metal framing through high density mineral wool continuous exterior board insulation and wall sheathing into a metal stud backup wall system. IMETCO employs this specific connection method with the IntelliScreen™ complete rainscreen assembly and other vertical wall assemblies.
Consider a critical scenario of a maximum weight metal panel, maximum thickness insulation board, and minimum gauge stud wall at maximum spacing (ref. Fig. A).